TESND – DC/DC CONVERTERS WITH WIDE INPUT VOLTAGE RANGE

Standard class DC/DC Converters for harsh environment with output power from 20...1200W. ‏

STANDARD class – modules for harsh environment and industrial equipments featuring parameters that fully conform with market requirements. The range of products in this series is less subject to changes; therefore, are ideal modules for long-term (serial) projects.

Standard Class

Application areas: Telecommunications, Industrial automation, Avionics, sea and land transport



TESND20

  • Class: Industrial, power density up to 3250 W/dm3 (53 W/In³)
  • High efficiency ≥ 85%
  • Low profile 10 mm design
  • Working case temperature –40°С…+110°С, for special request up to -60°С…+130°С
  • Output power 20 W, for special order up to 30W
  • One, two or three output channels
    (one of which is galvanically isolated from others)
  • Input voltage ranges: 10,5…40 VDC, 17…80 VDC
  • Output voltage adjustment, remote on/off
  • Max capacitance 1000 µF (for Uout=5 VDC)
  • Metal case, with mounting flanges and without flanges
  • Feedback for any output channel
  • PSU optimized budget version may be offered after individual project evaluation


TESND30

  • Class: Industrial, power density up to 2450 W/dm3 (40 W/In³)
  • High efficiency ≥ 85%
  • Low profile 10 mm design
  • Working case temperature –40°С…+110°С, for special request up to -60°С…+130°С
  • Output power 30 W, for special order up to 50W
  • One, two or three output channels
    (one of which is galvanically isolated from others)
  • Input voltage ranges: 10,5…40 VDC, 17…80 VDC
  • Output voltage adjustment, remote on/off
  • Max capacitance 4000 µF (for Uout=5 VDC)
  • Metal case, with mounting flanges and without flanges
  • Feedback for any output channel
  • PSU optimized budget version may be offered after individual project evaluation


tesnd50

  • Class: Industrial, power density up to 3120 W/dm3 (51 W/In³)
  • High efficiency ≥ 86%
  • Low profile 10 mm design
  • Working case temperature –40°С…+110°С, for special request up to -60°С…+130°С
  • Output power 50 W, for special order up to 80W
  • One, two or three output channels
    (one of which is galvanically isolated from others)
  • Input voltage ranges: 10,5…40 VDC, 17…80 VDC
  • Output voltage adjustment, remote on/off
  • Max capacitance 6000 µF (for Uout=5 VDC)
  • Metal case, with mounting flanges
  • Feedback for any output channel
  • PSU optimized budget version may be offered after individual project evaluation


TESND80

  • Class: Industrial, power density up to 3410 W/dm3 (56 W/In³)
  • High efficiency ≥ 86%
  • Low profile 10 mm design
  • Working case temperature –40°С…+110°С, for special request up to -60°С…+130°С
  • Output power 80 W, for special order up to 150W
  • One, two or three output channels
    (one of which is galvanically isolated from others)
  • Input voltage ranges: 10,5…40 VDC, 17…80 VDC
  • Output voltage adjustment, remote on/off
  • Max capacitance 15000 µF (for Uout=5 VDC)
  • Metal case, with mounting flanges
  • Feedback for any output channel
  • PSU optimized budget version may be offered after individual project evaluation


TESND200

  • Class: Industrial, power density up to 4070 W/dm3 (67 W/In³)
  • High efficiency ≥ 88%
  • Low profile 13 mm design
  • Working case temperature –40°С…+110°С, for special request up to -60°С…+130°С
  • Output power 200 W, for special order up to 300W
  • Input voltage ranges: 10,5…40 VDC, 17…80 VDC
  • Output voltage adjustment, remote on/off
  • Max capacitance 5400 µF (for Uout=12 VDC)
  • Metal case, with mounting flanges
  • PSU optimized budget version may be offered after individual project evaluation


TESND300

  • Class: Industrial, power density up to 3630 W/dm3 (59 W/In³)
  • High efficiency ≥ 88%
  • Low profile 13 mm design
  • Working case temperature –40°С…+110°С, for special request up to -60°С…+130°С
  • Output power 300 W, for special order up to 500W
  • Input voltage ranges: 10,5…40 VDC, 17…80 VDC
  • Output voltage adjustment, remote on/off
  • Max capacitance 8000 µF (for Uout=12 VDC)
  • Metal case, with mounting flanges
  • PSU optimized budget version may be offered after individual project evaluation


TESND600

  • Class: Industrial, power density up to 4320 W/dm3 (71 W/In³)
  • High efficiency ≥ 88%
  • Low profile 15 mm design
  • Working case temperature –40°С…+110°С, for special request up to -60°С…+130°С
  • Output power 600 W, for special order up to 1200W
  • Input voltage ranges: 17…80 VDC
  • Output voltage adjustment, remote on/off
  • Max capacitance 15000 µF (for Uout=12 VDC)
  • Metal case, with mounting flanges
  • PSU optimized budget version may be offered after individual project evaluation


TESND1200

  • Class: Industrial, power density up to 4060 W/dm3 (66 W/In³)
  • High efficiency ≥ 90%
  • Low profile 16 mm design
  • Working case temperature –40°С…+110°С, for special request up to -60°С…+130°С
  • Output power 1200 W, for special order up to 2400W
  • Input voltage ranges: 17…80 VDC
  • Output voltage adjustment, remote on/off
  • Max capacitance 20000 µF (for Uout=15 VDC)
  • Metal case, with mounting flanges
  • PSU optimized budget version may be offered after individual project evaluation